39 research outputs found

    What is the potential for pipe to pipe interactions in energy piles?

    Get PDF

    Temperature response functions (G-functions) for single pile heat exchangers

    Get PDF
    Foundation piles used as heat exchangers as part of a ground energy system have the potential to reduce energy use and carbon dioxide emissions from new buildings. However, current design approaches for pile heat exchangers are based on methods developed for boreholes which have a different geometry, with a much larger aspect (length to diameter) ratio. Current methods also neglect the transient behaviour of the pile concrete, instead assuming a steady state resistance for design purposes. As piles have a much larger volume of concrete than boreholes, this neglects the significant potential for heat storage within the pile. To overcome these shortcomings this paper presents new pile temperature response functions (G-functions) which are designed to reflect typical geometries of pile heat exchangers and include the transient response of the pile concrete. Owing to the larger number of pile sizes and pipe configurations which are possible with pile heat exchangers it is not feasible to developed a single unified G-function and instead upper and lower bound solutions are provided for different aspects ratios

    G-Functions for multiple interacting pile heat exchangers

    Get PDF
    Pile heat exchangers – where heat transfer pipes are cast into the building piled foundations – offer an opportunity to use ground energy systems without the additional construction costs related to the provision of special purpose heat exchangers. However, analysis methods for pile heat exchangers are still under development. In particular there is an absence of available methods and guidance for the amount of thermal interaction that may occur between adjacent pile heat exchangers and the corresponding reduction in available energy that this will cause. This is of particular importance as the locations of foundation piles are controlled by the structural demands of the building and cannot be optimised with respect to the thermal analysis. This paper presents a method for deriving G-functions for use with multiple pile heat exchangers. Example functions illustrate the primary importance of pile spacing in controlling available energy, followed by the number of piles within any given arrangement. Significantly it was found that the internal thermal behaviour of a pile is not influenced appreciably by adjacent piles

    Influences on the thermal efficiency of energy piles

    Get PDF
    Energy piles have recently emerged as a viable alternative to borehole heat exchangers, but their energy efficiency has so far seen little research. In this work, a finite element numerical model is developed for the accurate 3D analysis of transient diffusive and convective heat exchange phenomena taking place in geothermal structures. The model is validated by reproducing both the outcome of a thermal response test carried out on a test pile, and the average response of the linear heat source analytical solution. Then, the model is employed to carry out a parametric analysis to identify the key factors in maximising the pile energy efficiency. It is shown that the most influential design parameter is the number of pipes, which can be more conveniently increased, within a reasonable range, compared to increasing the pile dimensions. The influence of changing pile length, concrete conductivity, pile diameter and concrete cover are also discussed in light of their energetic implications. Counter to engineering intuition, the fluid flowrate does not emerge as important in energy efficiency, provided it is sufficient to ensure turbulent flow. The model presented in this paper can be easily adapted to the detailed study of other types of geothermal structures

    The Thermal Behaviour of Three Different Auger Pressure Grouted Piles Used as Heat Exchangers

    Get PDF
    Three auger pressure grouted (APG) test piles were constructed at a site in Richmond, Texas. The piles were each equipped with two U-loops of heat transfer pipes so that they could function as pile heat exchangers. The piles were of two different diameters and used two different grouts, a standard APG grout and a thermally enhanced grout. Thermal response tests, where fluid heated at a constant rate is circulated through the pipe loops, were carried out on the three piles, utilising either single or double loops. The resulting test data can be used to determine the surrounding soil thermal conductivity and the pile thermal resistance, both essential design parameters for ground source heat pump systems using pile heat exchangers. This paper uses parameter estimation techniques to fit empirical temperature response curves to the thermal response test data and compares the results with standard line source interpretation techniques. As expected, the thermal response tests with double loops result in smaller thermal resistances than the same pile when the test was run with a single loop. Back analysis of the pile thermal resistance also allows calculation of the grout thermal properties. The thermally enhanced grout is shown to have inferior thermal properties than the standard APG grout. Together these analyses demonstrate the importance of pile size, grout thermal properties and pipe positions in controlling the thermal behaviour of heat exchanger piles

    Comparison of two different models for pile thermal response test interpretation

    Get PDF
    Thermal response tests (TRTs) are regularly used to characterise the thermal resistance of borehole heat exchangers and to assess the thermal conductivity of the surrounding ground. It is becoming common to apply the same in situ testing technique to pile heat exchangers, despite international guidance suggesting that TRTs should be limited to hole diameters of 152 mm (6 in.). This size restriction arises from the increased thermal inertia of larger diameter heat exchangers, which invalidates the assumption of a steady state within the concrete needed to interpret the test data by traditional line source analysis techniques. However, new methods of analysis for pile heat exchangers have recently been developed that take account of the transient behaviour of the pile concrete. This paper applies these new methods to data from a multi-stage TRT conducted on a small diameter test pile. The thermal conductivity and thermal resistance determined using this method are then compared with those from traditional analytical approaches based on a line source analysis. Differences between the approaches are discussed, along with the observation that the thermal resistance may not be constant over the different test stages

    Thermal Response Testing of Large Diameter Energy Piles

    Get PDF
    Energy piles are a novel form of ground heat exchanger (GHE) used in ground source heat pump systems. However, characterizing the pile and ground thermal properties is more challenging than for traditional GHEs. Routine in-situ thermal response testing (TRT) methods assume that steady state conditions in the GHE are achieved within a few hours, whereas larger diameter energy piles may take days or even weeks, thereby incurring significant costs. Previous work on pile TRTs has focused on small diameters up to 450 mm. This paper makes the first rigorous assessment of TRT methods for larger diameter piles using field and laboratory datasets, the application of numerical and analytical modelling, and detailed consideration of costs and program. Three-dimensional numerical simulation is shown to be effective for assessing the data gathered but is too computationally expensive for routine practice. Simpler fast run time steady state analytical models are shown to be a theoretically viable tool where sufficient duration test data is available. However, a new assessment of signal to noise ratio (SNR) in real field data shows how power fluctuations cause increased uncertainty in long duration tests. It is therefore recommended to apply transient models or instead to carry out faster and more cost-effective borehole in-situ tests for ground characterization with analytical approaches for pile characterization

    Energy performance of diaphragm walls used as heat exchangers

    Get PDF
    The possibility of equipping diaphragm walls as ground heat exchangers to meet the full or partial heating and cooling demands of overlying or adjacent buildings has been explored in recent years. In this paper, the factors affecting the energy performance of diaphragm walls equipped as heat exchangers are investigated through finite element modelling. The numerical approach employed is first validated using available experimental data and then applied to perform parametric analyses. Parameters considered in the analysis include panel width, the ratio between the wall and excavation depths, heat transfer pipe spacing, concrete cover, heat-carrier fluid velocity, concrete thermal properties and the temperature difference between the air within the excavation and the soil behind the wall. The results indicate that increasing the number of pipes by reducing their spacing is the primary route to increasing energy efficiency in the short term. However, the thermal properties of the wall concrete and the temperature excess within the excavation space are also important, with the latter becoming the most significant in the medium to long term. This confirms the benefits of exploiting the retaining walls installed for railway tunnels and metro stations where additional sources of heat are available

    A comparison of laboratory and in situ methods to determine soil thermal conductivity for energy foundations and other ground heat exchanger applications

    Get PDF
    Soil thermal conductivity is an important factor in the design of energy foundations and other ground heat exchanger systems. It can be determined by a field thermal response test, which is both costly and time consuming, but tests a large volume of soil. Alternatively, cheaper and quicker laboratory test methods may be applied to smaller soil samples. This paper investigates two different laboratory methods: the steady-state thermal cell and the transient needle probe. U100 soil samples were taken during the site investigation for a small diameter test pile, for which a thermal response test was later conducted. The thermal conductivities of the samples were measured using the two laboratory methods. The results from the thermal cell and needle probe were significantly different, with the thermal cell consistently giving higher values for thermal conductivity. The main difficulty with the thermal cell was determining the rate of heat flow, as the apparatus experiences significant heat losses. The needle probe was found to have fewer significant sources of error, but tests a smaller soil sample than the thermal cell. However, both laboratory methods gave much lower values of thermal conductivity compared to the in situ thermal response test. Possible reasons for these discrepancies are discussed, including sample size, orientation and disturbance